Landlord, Homeowner & Business Certificates
An EICR means inspecting and testing everything hard-wired into a property, then recording in a certificate whether it remains safe to use. ATF Electrics runs out of Wolverhampton, about fifteen minutes up the road from Sedgley, so DY3 addresses and the Gornals sit comfortably inside our normal working area.
Sedgley sits between Wolverhampton and Dudley with Beacon Hill above it, and the housing runs from the old village core and its terraces out to the larger estates built around them. For testing that means a genuine mix: rewireable boards still in service, part-rewires done in stages, sound installations let down by one poor alteration, and a good number of properties held as rentals. None of it is unusual, and none of it needs dressing up.
An Electrical Installation Condition Report takes in the board, every circuit running off it, the state of the earthing arrangement and main bonding, and a working sample of the accessories and lighting points. Each finding is coded — danger that is present gets a C1, anything potentially dangerous a C2, a worthwhile improvement a C3, and FI covers whatever the inspection cannot settle on the day. The installation then goes down overall as Satisfactory or Unsatisfactory — the document your agent, your insurer or the council will ask to see.
The part people here tend to value most is having the codes explained properly: what genuinely has to be put right, what is only a recommendation, and what somebody else's quote may have exaggerated. There is no obligation to have the remedial work done by us. The wider service is on the EICR page, everything local is on the electrician in Sedgley page, business premises come under commercial electrical work, and there is a sister page covering EICR testing in Bilston. Get a free quote whenever it suits.
Each circuit inspected and tested to the 18th Edition, coded fairly, and written up in words that make sense.

The board comes open and every circuit is identified. Rewireable fuse units, boards carrying devices from three different makers and circuits nobody ever labelled are all regulars in older DY3 property — we record what is actually there rather than what ought to be.

Main earthing and the protective bonding to gas and water get traced and measured. In terraced and older stock this is the most common shortfall we come across, particularly after a boiler swap or a bathroom refit.

A sample of accessories is taken apart and tested for polarity, secure connections and signs of overheating, including anything running out to a garage, a shed or an outside supply.

Protective devices are measured for their actual trip times. Where a board is simply too old to give the protection now expected, that is written down as a finding and explained — not used as a sales pitch.

You get the full report with each observation coded, an overall result, and a conversation about what it actually means. That is the paperwork your tenant, letting agent or insurer will want, and the council too if it ever asks.
Four stages, first message through to certificate.
Give us the property and roughly when it was built, by phone, WhatsApp or the estimator, and we will quote it without coming out.
A time is agreed that works for tenants, for you, or for whatever deadline is driving it.
Testing runs circuit by circuit, and the power is only off where and when it has to be.
The coded report follows, with a call to go through anything marked C1, C2 or FI.
Need something other than an inspection in Sedgley? The same electrician covers the rest, and the neighbouring towns get the same EICR service.
What DY3 landlords, homeowners and agents ask us before booking.
It comes down to how many circuits and boards there are rather than the postcode. A one-board terrace is quick work; a large semi with a garage or workshop on its own supply takes considerably longer. Give us the property and its size and the figure we quote is the figure you pay. Request a free quote.
It is a legal requirement. The Electrical Safety Standards in the Private Rented Sector (England) Regulations put a five-year ceiling on how long a privately rented English home can go without a valid report, oblige you to hand the tenant a copy, and let the council demand one. Around Sedgley the council in question is Dudley.
C1 flags danger that is present right now and has to be dealt with at once. C2 covers something potentially dangerous, which must be put right before the report can pass. C3 is a recommendation only and will not fail anything. FI is used where a point cannot be settled without digging further. Record either a C1 or a C2 and the overall outcome is Unsatisfactory.
It happens, and it is often more than the codes require. We will read another electrician's report through with you and tell you which items genuinely have to be corrected and which are recommendations. Sometimes a rewire is the honest answer; frequently it is not.
The village and the roads around it, Upper and Lower Gornal, Woodsetton, Cotwall End and the estates running towards Coseley — DY3 generally, plus the Wolverhampton side above it.
Between two and four hours covers most homes around here; larger properties and second boards run on longer. We give you the likely window at booking, so nobody is caught out when circuits start going off.
Real reviews from customers across Wolverhampton & the West Midlands. You deal directly with Adam, every time.
Adam visited our property to carry out the EICR inspection. He was very friendly, professional, and punctual. Overall, it was a very smooth and positive experience. I would definitely recommend Adam to anyone looking for a reliable and professional electrician.
Adam carried out an EICR on our property and I was really impressed with his service. Communication was excellent from start to finish, he was transparent with pricing, and provided a clear breakdown of any issues.
Had a problem on a Sunday morning — by Sunday afternoon it was sorted. Found the problem straight away. Polite and well mannered, would certainly recommend him to anyone.
Adam is an excellent electrician — very reliable, professional, clean and tidy throughout his work. Arrived on time, very efficient. Highly recommended.
Excellent! Had a bathroom fan and several sockets channelled and fitted. Adam explained everything and answered all of our questions to make sure we got the fittings that suited our needs. Worked late into a Sunday evening to get the job finished, and even tidied as he went along. Would recommend!
Adam is a true professional — nothing was too much trouble to make sure my requirements for installing my new fire were met. He installed a connection from a spur and did a top job. 5 star service, would definitely recommend.
Absolutely fantastic service, from start to finish. Very professional, fully knowledgeable and friendly. Highly recommend.
He was very prompt in fitting me in. Polite and helpful, and the price was cheaper than expected. Definitely recommended.
Absolutely fantastic service. Adam was on time, very professional, very knowledgeable and polite. Cannot fault his work and will definitely be using him again for any future work.
Came to me to check the electrics and make sure all is safe in a shed I built in the garden. Did a very thorough job! Very friendly and professional.
Very helpful, quick and efficient — would book again for sure.
I had a partial power outage. Adam came over very quickly and sorted out the problem. No further costs beyond the call-out charge, which was explained when I called. Very pleasant, courteous and professional. Will not hesitate to use again.
Sedgley covers a lot of ground for one name — the old village centre and its terraces, the estates that grew out from it, and the Gornals running down towards Dudley, with Beacon Hill sitting over the lot. The property is as mixed as anywhere in the Black Country, so we test everything and assume nothing.
Free, no-obligation quotes for landlord, homeowner and business inspections throughout DY3.
All work is completed by qualified and certified electricians, with relevant approvals and documentation provided where required.