Landlord, Homeowner & Commercial Certificates
Wiring does not have to look dangerous to be dangerous. An EICR inspects and tests the fixed installation, then puts a written verdict on it. ATF Electrics runs out of Wolverhampton and Willenhall sits directly between us and Walsall, so WV12 and WV13 are firmly on our patch for landlords, owners and businesses.
Willenhall made its name on lock-making, and the housing built around that trade is still standing: dense terraced streets close to the town centre, a good share of them rented, and most of them altered more than once. Those are the properties where rewirable fuse boards, borrowed neutrals and pre-1990s cable survive quietly behind a modern-looking socket front. Head outward to New Invention and Short Heath and the stock gets newer, where the observations shift towards bonding, RCD coverage and DIY additions rather than the cable itself.
An Electrical Installation Condition Report is a measured test of the whole fixed installation — consumer unit, every final circuit, earthing, main protective bonding and a sample of accessories throughout. Every defect gets a code: C1 marks danger present, C2 marks something potentially dangerous, C3 records a recommended improvement, and FI flags anything that cannot be judged without further investigation. The report closes on a single Satisfactory or Unsatisfactory outcome, which is the part an agent, insurer, lender or solicitor goes straight to.
Adam does the testing and writes the report, so there is no gap between what was found and what you are told. There is more on the EICR service page, everything else we do as an electrician in Willenhall, and the same inspection next door in Walsall. Trade units and shops fall under commercial electrical work, and you can get a free quote whenever it suits.
Every circuit tested to BS 7671, every defect coded, and a report you can hand straight to an agent.

The consumer unit comes open and every circuit is identified. Loose terminations, heat damage, parts from different manufacturers sharing one enclosure, missing labelling and old rewirable fuse carriers are all noted and coded properly.

Main earthing and the bonding to gas, water and structural steel are traced and verified for size and continuity. In Willenhall’s older rented terraces, missing or undersized bonding is the single most frequent thing we write up.

Sockets, switches and light points are sampled and opened: polarity, terminations, heat damage, and whatever has been added over the years to feed a workshop, a garage or an outbuilding at the back.

Every RCD and RCBO is timed on the tester. Where a board offers only partial protection — common in a property that had a part-rewire and never a full one — we set out exactly which circuits are left without it.

You end up with the full schedule, each observation coded, and one clear outcome to give a tenant, an agent, an insurer or a buyer. We explain it on the phone rather than leaving you to interpret a table of codes.
Four stages between first contact and the certificate.
Message us on WhatsApp, ring, or use the estimator. Property type and rough age is enough for a firm price without a site visit.
We work around tenants, agents and trading hours — including short-notice slots when a tenancy or a sale is up against a date.
Circuit by circuit, isolating in stages, with the power off for the shortest time the testing allows.
The certificate and coded schedule arrive by email, followed by a phone call about anything at C1, C2 or FI.
Need something other than an inspection in Willenhall? The same electrician covers the rest, and the neighbouring towns get the same EICR service.
What Willenhall landlords, agents and homeowners ask us most often.
It comes down to circuits and boards rather than whether you are in WV12 or WV13. A small terrace on one board is straightforward; a converted property with two boards and an outbuilding supply is a bigger job. Send the details and we give a fixed price up front. Ask for a free quote.
At least every five years. The Electrical Safety Standards in the Private Rented Sector (England) Regulations require privately rented homes in England to hold a valid EICR, with a copy given to tenants and produced for the local authority on request. It is the question Willenhall landlords ask us most.
Two to four hours for a typical Willenhall house. Larger properties, extra boards or commercial premises take longer and are quoted that way, and we give you the realistic window at the point of booking.
C1 is danger present and needs immediate attention. C2 is potentially dangerous and must be rectified to pass. C3 is an improvement recommendation that does not fail the installation. FI means further investigation is required. A single C1 or C2 makes the overall outcome Unsatisfactory.
All of WV12 and WV13 — the town centre, New Invention, Short Heath and the streets running out towards Walsall and Bilston. We are ten to fifteen minutes away in Wolverhampton, so a same-day response is usually realistic.
Yes, and we would rather you felt free to. The coded report is yours whatever you decide. If you do want us to price the remedials, we quote only the items the codes require and list anything optional separately.
Real reviews from customers across Wolverhampton & the West Midlands. You deal directly with Adam, every time.
Adam visited our property to carry out the EICR inspection. He was very friendly, professional, and punctual. Overall, it was a very smooth and positive experience. I would definitely recommend Adam to anyone looking for a reliable and professional electrician.
Adam carried out an EICR on our property and I was really impressed with his service. Communication was excellent from start to finish, he was transparent with pricing, and provided a clear breakdown of any issues.
Asked for an emergency call-out on a Sunday afternoon — Adam did not hesitate and came in less than an hour. Found the fault instantly and laid out our options. Very polite, and didn't insist on what should be done — he let us decide.
Adam came straight away when he heard about our electric faults. He fixed all our problems, was professional, honest and got the job done. I would recommend his services to anyone who needs an electrician.
Absolutely fantastic service. Adam was on time, very professional, very knowledgeable and polite. Cannot fault his work and will definitely be using him again for any future work.
Needed some electric in my shed and Adam helped me sort this out swiftly and very professionally too. Super happy with my service and he cleaned up afterwards too, so that was a plus!
Absolutely brilliant service. Adam was always approachable and available to speak to. Very knowledgeable and willing to answer all questions without hesitation. The only electrician that came out and did a test on a Sunday! Thank you Adam.
Really impressed by the level of service I received. I needed 2 sockets moving and called for a quote — I had a quote the same day and a clear outline of what would happen and when. Everything happened exactly as organised.
Fabulous work, from beginning to end. Thorough and very respectful. Thank you!
Couldn't recommend Adam enough — top class service from start to finish, making sure I was aware of what's going on at every stage of the full rewire he completed on my property. Will definitely be using ATF in the future!
Great service, didn't rip me off. Would definitely recommend.
Adam fitted a new light to an inline fan in our bathroom. He came within an hour of my call and promptly sorted the issue. He was very polite and professional.
Willenhall’s lock-making history left it with rows of tight terraced housing near the centre and plenty of it in the rented sector, while New Invention and Short Heath add later estates on the outer edges. That mix is why an EICR here can go either way — a 1930s terrace with three generations of alterations behind the plaster, or a 1990s semi that only needs its bonding sorting. Either way, in WV12 or WV13, the test is the same and so is the coding.
Free, no-obligation pricing for a Willenhall EICR — rented, owner-occupied or commercial premises.
All work is completed by qualified and certified electricians, with relevant approvals and documentation provided where required.